Quantification of Monochloropropanediol Monoesters by Normal-Phase LC-MS/MS Analysis

(ORIST)
oHirofumi Sato, Yomi Watanabe, Motohiro Shizuma

The qualification and quantification of monochloropropanediol (MCPD) monoesters were achieved by normal phase liquid chromatography utilizing C60 column coupled with tandem mass spectrometry (LC-MSMS). MCPD monoesters which have fatty acyl group were separated without overlap prior to MS/MS within 15 min and were accurately quantified. Moreover, even peak-overlapped 3-MCPD-monoesters in chromatogram could be also quantified applying multiple reaction monitoring (MRM).